Insight
One atomic statement made by an expert, a student or a publication, with its evidence status.
Expert Open for expert review · What do these labels mean?
Adding internal blackout to a translucent envelope would mean doubling the system across “100 kilometres of line”, doubling price and construction complexity — and in a clean industrial process textiles that collect dust are not allowed.
— Paraphrased from the lecture
| Where in the source | Q&A — anchor: “including blackouts on the inside” |
| Confidence | high |
Context
In the Q&A, following the discussion of light pollution from the translucent envelope of the Frýdek-Místek food factory, a student asked how inefficient it would be to add blackouts on the inside of the wall. Goláň answered first, Novotný added the construction and hygiene reasons.
From the transcript
Well, I mean, it’s not inefficient. You could do it for sure, but it’s another technical sort of needs you’re introducing to the building and then creating one of the complex system[s]. It could be done for sure. […] But then you have, you know, like, I don’t know, like 100 kilometers of line. […] For example, in here it will be a construction issue because […] they have to be doubled, […] which is double the price and double the [complexity, garbled in the transcript] by constructing, because inside there is a very clean industrial process. So there are no textile, no nothing which could collect [dust], et cetera.
Automatic transcript, Q&A, 01:18:49. Lightly cleaned: repeated words and fillers removed, omissions marked […], editorial insertions in [brackets].
Connections
- Source: Challenge the perception of industrial architecture as ‘boxing’
- Challenges: Visual impact of logistics on neighbours
Something wrong or missing? Suggest a correction