Where the national standard has no upper bound, LEED’s Useful Daylight Illuminance (work surface, around a 3,000 lux upper limit) and Annual Sunlight Exposure (floor-measured, 1,000 lux exceeded for more than 250 hours a year, expressed as a percentage of area) do — and ASE counts only areas actually intended for office work.
— Paraphrased from the lecture
| Where in the source | ~01:30–01:35 — anchor: “which already has this upper limit set up” |
| Confidence | high |
Context
Ellen Krečková (EkoWATT), speaking in Czech with live English translation, presents the daylight metrics of her study of an office building in Prague. Because the Czech daylight factor has no upper limit, she uses LEED metrics that have one.
From the transcript
[…] because the [Czech] standards don’t allow this, we have UDI, useful daylight [illuminance], which is part of [LEED], which already has this upper limit set up. It’s been calculated on a surface of a table, like a workspace, and we’re looking for the value of 3000 [lux] on that surface. […] there’s another one also used in [LEED], annual sunlight exposure. So it’s for full year of sunlight, it’s calculated on the floor and the cut off value is 1000 [lux] and also it has to be more than 250 hours per year. […] the metric is calculated in percentage of [area] […] And the percentage is calculate[d] only from the areas which are meant to be administrative work or the office, not for the kitchen and, you know, the hallways.
Automatic transcript, presentation, 01:30:21 and 01:33:51. Lightly cleaned: repeated words and fillers removed, omissions marked […], editorial insertions in [brackets].
Connections
- Source: Criteria for a Green Building – Beyond energy performance LEED - BREEAM - WELL
- Challenges: Deep, dark and noisy workplaces
- Metrics: Daylight autonomy