Insight
One atomic statement made by an expert, a student or a publication, with its evidence status.
Expert Open for expert review · What do these labels mean?
Ranked as systems the story inverts: a concrete slab is high, steel-beam-and-slab still high, CLT the most efficient structural form. Intensity and usage must be read together.
— Paraphrased from the lecture
| Where in the source | ~00:48 — anchor: “these figures are per kilogram of material” |
| Confidence | high |
Context
Right after revealing the per-kilogram ranking of five materials, Paul Astle (Ramboll) re-ranks them by how they are used in structures.
From the transcript
And this is where I really want you to think carefully, because these figures are per kilogram of material, which is often quoted in literature. They talk about carbon intensity per kilogram, but actually when we talk about buildings, that’s really meaningless because what’s important is how much those materials we use for a given application. […] So if we just look at a concrete slab, that would be quite high. We look at a steel beam and concrete slab, it’s also pretty high still. CLT then is the most efficient form of construction at a structural level. […] Of course the carbon intensity of materials is important directly, but also what’s important is understanding how we use those materials. So it’s really important we have both.
Automatic transcript, presentation, 00:48:00. Lightly cleaned: repeated words and fillers removed, omissions marked […], editorial insertions in [brackets].
Connections
- Source: Net Zero That Holds Up – Whole-Life Carbon, Design Choices, and Delivery
- Challenges: Embodied carbon of new and demolished warehouses
- Metrics: Embodied carbon intensity
Something wrong or missing? Suggest a correction