Trade-off · published
A recurring conflict between two design aims or metrics, found in the student projects or reported by experts and publications, with how the projects handled it.
| Summary | Translucent roof panels and roof lights cut lighting energy, but in hot climates they let in heat that harms thermal comfort. |
| Status | published |
The conflict
Lighting is the largest energy use in a dry warehouse, so daylight through the roof is an obvious saving. The same roof lights let in solar heat, which raises indoor temperatures in hot climates; the two metrics have to be weighed together.
What experts and publications say
- Translucent roofs trade lighting carbon for heat — Roof lights cut lighting energy and possibly embodied carbon but raise indoor heat in hot climates, so the metrics must be weighed together.
- Lighting is 65–95% of a dry warehouse’s energy — In non-refrigerated warehouses lighting dominates energy use, and LED retrofits cut lighting electricity costs by up to 70%.
Paraphrased from the publication; see each insight for its source and evidence status.
Connections
- Metrics in conflict: Daylight autonomy, Thermal comfort, Energy use intensity, Embodied carbon intensity
- Expert insights: Translucent roofs trade lighting carbon for heat, Lighting is 65–95% of a dry warehouse’s energy
- Problem statements: Trade-offs across design and value
Something wrong or missing? Suggest a correction