Insight
One atomic statement made by an expert, a student or a publication, with its evidence status.
Expert Open for expert review · What do these labels mean?
The figure fell through roughly 8.9 at tender to about 6.6 once generic EPDs were replaced with specific ones.
— Paraphrased from the lecture
| Where in the source | ~00:35 — anchor: “kilos of CO2 equivalent per” |
| Confidence | check — the starting value reads “2” in the transcript |
Context
The embodied carbon of the Bestseller building’s materials, calculated with the Danish LCA method, in kg CO2e per m² of floor area per year. The starting value is garbled in the automatic transcript, which reads ‘around 2’; since the later values are higher, the claim bank reads it as about 12.
From the transcript
But we started out with […] a baseline where we were around [1]2 kilos of CO2 equivalent per square meter per year, until when we tendered the project, where we brought the number down to around 8.9, and then in the further process, where all the generic EPDs were replaced with more specific ones, we got down to 6.6. And we have not seen the final calculation, but it looks like […] we remain within this territory of around 6.6 kilos per square meter per year, or perhaps even a little bit lower.
Automatic transcript, presentation, 00:47:07. Lightly cleaned: repeated words and fillers removed, omissions marked […], editorial insertions in [brackets].
Transcription
The number or wording may have been garbled in the transcript, or the speaker hedged it (the baseline figure is garbled; 8.9 and 6.6 are clear). To be checked against the recording.
Connections
- Source: Big Box, Small Footprint – Lessons from Bestseller’s Low-Carbon Logistics Campus
- Challenges: Embodied carbon of new and demolished warehouses
- Metrics: Embodied carbon intensity
- Reference projects: Bestseller Logistics Center West
Something wrong or missing? Suggest a correction