Phase-one capacity leaves part of the terminal unautomated, running manual racking and forklifts; point loads of ~6 tonnes through the wheels made timber structurally unreasonable there. Elsewhere the timber slab still needs a concrete topping; offices keep bare timber.

— Paraphrased from the lecture

Where in the source~00:26 and ~1:38 (Q&A) — anchor: “the loads from the lifting equipment”
Confidencehigh

Context

Why part of the otherwise timber terminal is built in concrete. The area is reserved for equipment of a future third high-bay warehouse; until then it is used for manual storage with forklifts. A student later asked whether robots enable timber while forklifts require concrete.

From the transcript

[…] that area will from the start be used for manual warehousing, which is basically large racks, and where you move the goods around with forklifts […] that creates a loading requirement on the floor plates, which means that in this area […] it did not make sense to construct this part of the building out of timber […] A forklift is pushing its wheels down into the floor with around 6 tons. So if we did that in timber, we would get marks within our slabs. — (Q&A) It was maybe more the warehousing requirement […] due to the phasing, there is a large part of the terminal where we actually don’t have any equipment in phase one.

Automatic transcript, presentation, 00:30:27, and Q&A, 01:38:11. Lightly cleaned: repeated words and fillers removed, omissions marked […], editorial insertions in [brackets].

Connections