Strategy · published
A repeatable evidence workflow from the student projects — which metrics to calculate, with which tool or method, and the decision it led to.
| Summary | Wind data and simulation test how the arrangement and orientation of volumes shelter outdoor space or channel wind for cooling. |
| Tool or method | Ladybug wind rose and Eddy3D CFD simulation in Grasshopper |
| Status | published |
The question it answers
Which arrangement and orientation of the volumes gives shelter, or catches the wind where it is wanted?
How it works
- Plot a wind rose from a weather file for the site, by season if wind changes over the year.
- Model layout variants and simulate wind speed at pedestrian height (about 1.5 m) with CFD.
- Compare the variants with a reference wind speed and check that corners do not accelerate the wind.
- Choose and orient the layout that gives the needed shelter or airflow.
In the student projects
- Sara Sulollari — Ladybug and Eddy3D in Grasshopper. Pedestrian-level wind speed: typical waterfront 6.0 m/s vs proposal 3.97 m/s; Wind conditions: winter wind up to about 25.2 m/s, strongest from the east. Decision: “The wind simulations showed the U-shaped container layout gave the strongest shelter, so it was chosen for the container wind buffer, with corners softened below 90° to avoid speeding up the wind.”
- Robin Jesenský — Ladybug in Grasshopper, and a wind atlas map. Wind conditions: ≈9.82 m/s at 100 m height; speeds 0.5–27.3 m/s, calm 1.75% of the time. Decision: “Wind data (wind atlas and Ladybug wind rose) supported siting the data centre on a windy, non-protected coastal location near Grindavík and orienting the modular shells to capture ground wind for passive air cooling.”
Values and decisions as reported by the student; see each case study for the page in the portfolio.
Where it falls short
- Robin Jesenský uses wind data to site and orient the building; no airflow simulation of the shells is reported.
- Neither case study reports a pedestrian comfort criterion, such as Lawson, for the wind speeds.
Where are the ambitions, metrics and tools?
They appear automatically below under Connections, and in Obsidian under the
auto_properties.
Connections
- Case studies: Sara Sulollari, Robin Jesenský
- Metrics it calculates: Pedestrian-level wind speed, Wind conditions
- Tools: Ladybug, Eddy3D, Grasshopper
- Ambitions (through its projects): Compact footprint, Logistics as part of the city, Low embodied carbon, Low energy and water demand, Modular and prefabricated architecture, Outdoor comfort
Something wrong or missing? Suggest a correction