Strategy · published
A repeatable evidence workflow from the student projects — which metrics to calculate, with which tool or method, and the decision it led to.
| Summary | An energy estimate or simulation of the building, before and after a design move, shows how much heated area or envelope changes save. |
| Tool or method | manual / formula (benchmark × heated area) or a building energy simulation (Honeybee or a tool that is not named) |
| Status | published |
The question it answers
How much energy does a smaller heated zone or a better envelope save?
How it works
- Estimate the baseline: a benchmark intensity times floor area, or a monthly energy simulation of the existing or typical building.
- Model the design move, such as a smaller actively heated zone, insulation or an adaptive façade.
- Compare annual or monthly demand, split into heating, cooling, lighting and technology.
- Keep the move if the saving is significant, and size PV or other supply to the remaining demand.
In the student projects
- Elsa Hauksdottir — manual / formula. Heating energy demand: baseline 600,000 kWh/yr vs proposal 360,000 kWh/yr. Decision: “The energy estimate supported adaptive thermal zoning with manual movable partitions and foldable racks, so the active heated zone shrinks off-peak and the dormant area goes to public use.”
- Vladi Kostecki — an energy simulation tool that is not named. Energy use intensity: original envelope 48,000 kWh/month vs improved envelope 30,000 kWh/month, approx. 37.5% annual reduction. Decision: “Upgrade the envelope with insulation and sun-responsive façade panels (approx. 37.5% less energy).”
- Sara Gani — an energy simulation tool that is not named. Energy use intensity: before 220–280 kWh/m²a; after 110–160 kWh/m²a.
- Lindsay Daphne Macuja — Grasshopper energy model (probably Honeybee, inferred from the graphics). Energy use intensity: monthly peaks approx. 75,000 kWh in January/December. Decision: “The energy profile supported putting PV on the sawtooth roof.”
Values and decisions as reported by the student; see each case study for the page in the portfolio.
Where it falls short
- In Elsa Hauksdottir’s project the benchmark intensity is not cited, and two pages give different proposal values (360,000 and 300,000 kWh/yr).
- Two of four projects do not name the simulation tool.
Where are the ambitions, metrics and tools?
They appear automatically below under Connections, and in Obsidian under the
auto_properties.
Connections
- Case studies: Elsa Hauksdottir, Vladi Kostecki, Sara Gani, Lindsay Daphne Macuja
- Metrics it calculates: Heating energy demand, Energy use intensity
- Tools: Honeybee
- Ambitions (through its projects): Adaptable over time, Good neighbour, Green and productive roofs, Habitat and ecological connectivity, Healthy workplaces, Logistics as part of the city, Low embodied carbon, Low energy and water demand, Mixed use and function stacking, Public access and community use, Reuse of existing buildings, Safe sites with separated flows
Something wrong or missing? Suggest a correction