Project

An active logistics centre sits inside a former coal-power-station area that is being redeveloped into a green residential district, creating unsafe truck–pedestrian conflicts and cutting two public parks apart. The concept ‘Invisible Logistics’ aims to make the facility read as landscape rather than industry. Key moves are an artificial green hill and stepped walkable green roof terraces over the warehouse, a timber façade wrapping the building, a pedestrian tunnel and bridge linking the separated parks, and strict zoning that keeps the truck yard apart from staff and public routes. A Grasshopper geometry optimiser minimised envelope perimeter for a fixed 5,000 m² usable area and estimated façade costs, and a monthly energy simulation checked operational demand.

How the student framed the challenge

  • Urban integration of logistics buildings
  • Truck–pedestrian safety and site zoning
  • Reconnecting fragmented public green space
  • Stormwater and impervious surfaces on logistics sites

Metrics and evidence

Every metric the project used, as named by the student, with the value, the calculation and the portfolio page.

MetricStudent’s wordingValueHow it was calculatedToolPage
Pedestrian–vehicle conflict pointsPedestrian-Truck Crossing Points / Staff–Truck Crossing PointsExisting 4 → proposed 0Count of locations where pedestrian/staff/public routes intersect truck routes, mapped on the site flow-analysis plan for existing vs proposed layout.manual / formula6, 7, 9, 21
Parking capacityParking Capacity Provided / Staff Parking CapacityExisting 70 → proposed 80Count of car parking spaces on the site plan.manual / formula21
Green area ratioGreen Area RatioExisting 5% → proposed 40%Green (vegetated) area divided by total site area.not stated21
Impervious surface ratioImpervious Surface RatioExisting 85% → proposed 40%Sealed/impervious surface area divided by total site area.not stated21
Tree count and canopy coverTree Planting DensityExisting 5 → proposed 45 trees/haNumber of trees divided by site area in hectares.not stated21
Water reuse shareRainwater Reuse PotentialExisting 0% → proposed 65%Share of rainwater captured and reused; method not explained.not stated21
Publicly accessible areaPublicly Accessible Roof AreaExisting 0 → proposed 1,800 m²Area of walkable roof terraces open to the public, measured in the model.not stated21
WalkabilityConnected Public PathwaysExisting 0 → proposed 350 mLength of new public pedestrian routes (hill, tunnel, bridge, roof) linking the surrounding parks.not stated21
Construction costFacade Perimeter Optimization0 → 12% reductionEvolutionary solver minimises total wall length for a fixed 5,000 m² usable area (penalty for deviating from target area); reduction of perimeter vs baseline footprint.Grasshopper (Galapagos evolutionary solver)12, 21
Construction costFacade price / window price / final priceComputed live in the script; numbers not legibleScript computes façade area from height × perimeter, window area from a glazing percentage, multiplies each by a unit price and sums to a final envelope price.Grasshopper12
Energy use intensityEnergy performance simulation (kWh)Peak approx. 110,000 kWh in January (heating-dominated); summer peak approx. 83,000 kWh in July (cooling); lowest approx. 52,000–55,000 kWh in May/Sep/Oct (values read from chart)Building energy simulation of the proposed volume, broken down into heating, cooling, lighting and technology per month.Grasshopper energy simulation (plugin not named)13, 23

Tools

  • Grasshopper — Parametric geometry optimiser for building dimensions and envelope cost estimation; monthly energy simulation
  • Galapagos — Evolutionary solver minimising perimeter at fixed 5,000 m² usable area

Trade-offs

  • Not stated explicitly; the geometry optimiser balances façade perimeter (cost, heat loss) against the fixed usable-area target of 5,000 m².

Decision

The crossing-point and flow analysis led to a strict two-zone layout (truck area vs public/staff area) with zero pedestrian–truck crossings. The geometry optimiser fixed a compact footprint with about 12% less façade perimeter, and greening/permeability KPIs supported the green hill, intensive green roof and accessible roof terraces.

Open questions

  • Questionnaire KPIs such as truck turnaround time, dock accessibility efficiency, expansion potential, renewable energy potential and site utilisation efficiency are not quantified in the portfolio.
  • Calculation methods for rainwater reuse potential and green/impervious ratios are not documented.
  • No embodied carbon / LCA or biodiversity net gain calculation.